Couldn't load pickup availability
Free Shipping & Trusted Delivery
Enhanced Warranty
Personalized Training
Canta Esthetic's Fusion Plasma is an innovative beauty technology combining warm and cold plasma. This advanced treatment effectively tightens the skin, accelerates healing, and delivers a comprehensive rejuvenation experience.
Warm Plasma: Adopting advanced plasma technology (Fibroblast Promotion), warm plasma utilizes high-frequency plasma ionizing air gas, producing a large-area plasma arc (flare). Its precise energy gently acts on the skin's surface, promoting fibroblast regeneration and enhancing skin renewal.
What is real Cold Plasma?
True Cold Plasma must be generated using inert gases like helium or argon; otherwise, it remains classified as warm plasma.
Many devices on the market claim to use cold plasma, but without gas support, they are still warm plasma! Canta Esthetic's device uses helium as a conductor, ensuring the authenticity of true cold plasma technology. Devices without gas support are, in fact, warm plasma!
Functions and Benefits of Cold Plasma
✔ Powerful Antibacterial and Anti-Inflammatory effects: Cold plasma is suitable for treating various skin issues including acne, eczema, and psoriasis.
✔ Deep Disinfection: By utilizing ozone technology cold plasma provides powerful sterilization and environmental purification without the need for chemical agents.
✔ Enhanced Healing: With no heat, irritation, or redness, cold plasma directly soothes the skin and promotes faster recovery.
✔ Post-Treatment Repair: Cold plasma is especially effective and efficient after Fusion Plasma treatments, supporting antibacterial care, inflammation reduction, and accelerated healing. One whole-face treatment with Canta Esthetic takes only 20 minutes, delivering immediate visible results with ongoing improvement. Fast results, no waiting.
✔ Low-Invasive and Gentle: Compared to traditional plasma pens, warm plasma causes less damage to the epidermis. Its low-energy loss penetrates deeply into the cell layer without causing severe burning sensations.
✔ High Skin Firming Effect: Warm plasma rapidly stimulates collagen production, addressing skin laxity and signs of aging.
✔ Faster Recovery: Warm plasma energy cools quickly, causing minimal discomfort and eliminating the need for extended recovery time.
Comparison items |
Warm Plasma Technology ✔ |
Traditional Fibroblast Technology ❌ |
Treatment |
Non-invasive, gentle, and efficient |
Invasive, causing epidermal carbonization.
|
Pain |
Almost no pain, low temperature, and high efficiency |
painful, anesthesia required |
Treatment time |
15-20 minutes for the whole face |
Treatment take longer than 20 minutes |
Recovery period |
Short, only 2-3 days required |
Long, eschar caused in treatment takes 7-10 days to fall off |
Scope of application |
Applicable to the face, around the eyes, and neck. |
Mainly used for point-to-point small-scale treatment |
Appearance after treatment |
There is no eschar, only slight white spots |
Obvious black eschar, easy to cause scabs |
✅ Warm Plasma utilizes upgraded technology to reduce trauma and accelerate restoration, making it ideal for customers who want to tighten and lift their skin without a long recovery period!
Probe type |
Core functions |
Applicable issues |
Hyper Plasma Tip |
Deep sterilization promotes hair growth. |
Acne, eczema, dermatitis, hair loss |
Ozone Plasma Tip |
Anti-inflammatory and anti-acne skin barrier restoration |
Rosacea, hormone-dependent dermatitis, postoperative infection |
Diamond Plasma Tip |
Gently rejuvenation for the whole face glowing. |
Rough skin, nasal folds, dull faces
|
Derma Plasma Tip
|
Precisely bumpin' skin for deep wrinkles and tackling acne and scars |
Stretch marks, acne scars, nasolabial folds |
Plasma roller tip |
Large area skin lifting and firming, assisted with essence penetration |
Sagging neck and loosing facial contours |
Scalp Plasma Tip |
hair follicle activation and hair growth stimulation |
Hair loss, dandruff, hair follicle atrophy |
Warm Plasma Tip |
Gentle stimulation of collagen production anti-aging care, especially for sensitive skin |
Early aging issues including losing skin, enlarged pores |
Plasma Jet Tip |
Targeted tackling with pigmentation, realizing skin rejuvenation causing no wounds |
Melasma, freckles, age spots |
✔ Most customers achieve ideal results after just 1-2 treatments.
✔ Eye lift and skin renewal treatments show visible results after the first session, with continuous improvement lasting up to 90 days.
✔ Mild redness (typically subsides in 2-3 days; for the eye area, it may take 5-7 days)
✔ Slight swelling (more common around the eye area)
✔ No eschar or black scabs form, avoiding the trauma associated with traditional plasma pens
✔ Immediate skin-tightening effect with continuous improvement during the recovery process
⚠ Avoid scratching or peeling any scabs; allow your skin to heal naturally.
Ozone Plasma (Ozone Plasma Technology)
1. Installing the Ozone Plasma Probe: Remove the ozone plasma probe and insert it into the ozone probe adapter. Securely connect the adapter to the probe port.
2. Selecting Mode & Adjusting Power: On the touchscreen, select the Ozone Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Diamond Plasma (Diamond Plasma Technology)
1. Installing theDiamond Plasma Probe: Put the Diamond Plasma Probe through the Fixing Chuck and insert it into the Needle Holder. Insert the Needle Holder into the Probe Port and gently secure it with the Fixing Chuck.
2. Selecting Mode& Adjusting Power: On the touchscreen, select the Diamond Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Gold Plasma (Gold Plasma Probe)
1. Installing thegold plasma probe: Put the gold plasma probe through the fixing clamp and insert it into the needle holder. Insert the needle holder into the probe port and gently fix it with the fixing clamp.
2. Selecting Mode& Adjusting Power: On the touchscreen, select the Gold Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operation instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Warm Plasma (Warm Plasma Technology)
1. Installingthe Warm Plasma Probe: First, insert the Warm Plasma Probe through the lower part of the Needle Holder (see the figure). Then, insert the Needle Holder into the probe port and gently secure it with the Fixing Clip.
2. SelectingMode & AdjustingPower: On the touch screen select the Warm Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Hyper Plasma (Hyper Plasma Technology)
1. Installingthe Hyper Plasma Probe: Remove the Ultra Plasma Probe and insert the Ultra Adapter. Insert the needle into the needle holder, then the adapter, and finally the probe port.
2. SelectingMode & Adjusting Power: On the touch screen select the Hyper Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly. After use, please turn off the device and the gas tank, clean the probe with an alcohol-based disinfectant, and store it after drying.
Scalp Plasma (Scalp Plasma Technology)
1. Installing theScalp Plasma Probe: Take out the Scalp Plasma Probe and insert the Scalp Adapter. Insert the Needle into the Needle Holder, the Adapter, and the Probe Port.
2. Selecting Mode& Adjusting Power: On the touch screen select the Scalp Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Plasma Roller (Plasma Roller Technology)
1. Installing theplasma roller probe: Take out the required plasma roller probe and insert the roller adapter. Connect the probe port through the adapter.
2. Selecting Mode& Adjusting Power: On the touch screen select the Derma Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operation Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Plasma Jet Probe
1. Installing the Plasma Jet Probe: Please remove and connect the Plasma Jet Probe directly to the Probe Port.
2. Selecting Mode& Adjusting Power: On the Touch Screen select the Plasma Jet icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operation Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, please turn off the device and the gas tank, clean the probe with an alcohol-based disinfectant, and store it in a dry place.
⚠ Awareness
All probes must be cleaned with an alcohol-based disinfectant and stored until dry.
To avoid overheating, lift the Foot Switch at the recommended intervals.
After closing the device, store all probes and accessories properly.
Fusion Plasma adopts a non-invasive professional skin care technology to tighten the skin, fade acne scars, even out skin tone, and reduce pigmentation. It functions in effectively improving skin texture and enhancing skin translucency and firmness. It is essential to follow a scientific process after surgery to ensure the maximum effectiveness of treatment and prolong the care results.
1. Avoid sun exposure: Avoid exposure to the sun for 2-4 weeks before treatment, and avoid tanning, sunbathing, or using tanning spray.
2. Stop using irritating skin care products: To reduce skin irritation, avoid using skin care products containing ingredients such as fruit acids, A acids, salicylic acids, glycolic acids, etc.
3. Postpone other medical beauty projects: Avoid fillers, Botox, microneedles, and PRP within 21 days before treatment, and avoid laser or deep chemical peels within 90 days before treatment.
1. First 24 hours: Avoid applying any skin care products to allow the skin to repair naturally.
2. For the first 5 days, use unique post-operative care products to avoid possible irritation caused by ordinary skin care products.
3. Do not wear makeup for the first 48 hours, keep the skin clean, and avoid friction and contact with pollution sources.
4. First 1 week: Avoid steam, sauna, high-temperature environment, and strenuous exercise to avoid affecting skin healing.
5. Continue for 2-4 weeks: Use SPF30+ sunscreen to avoid UV exposure and prevent pigmentation and spots.
After Fusion Plasma treatment, the skin will gradually improve, and the effect can last 6-9 months. Depending on individual differences, some customers may need additional treatments, and each treatment should be separated by at least 4 weeks to ensure that the skin has enough time to repair and enhance the effect.
We offer comprehensive operation instructions for our customers, which include useful tips and suggestions. For every Canta Esthetic device, our customers can receive free training. Our certified beauticians provide personalized training for each Canta Esthetic device. Upon your request, free certification can also be provided after training.
We support Free shipping to 28 countries and regions:
USA, Canada, UK, Germany, France, Italy, Spain, Sweden, Denmark, Norway, Netherlands, Bulgaria, Belgium, Poland, Latvia, Czech Republic, Switzerland, Israel, Netherlands, Ireland, Japan, South Korea, Singapore, Hong Kong, Malaysia, Thailand, Australia, New Zealand.
If your country or region is not in the above list, please contact us.
For more details, please see:
Full shipping policy.
Full refund policy.
We understand that deciding to purchase a new beauty device isn't always easy. To ensure exceptional quality, all Canta Esthetic machines go through a stringent quality control process and come with a 36-month warranty. If you have any technical issues, you can always contact our expert team.
At Canta Esthetic, we specialize in providing high-quality aesthetics devices tailored to elevate your brand's presence and cater to your specific business needs.
Customization That Speaks Your Brand:
We understand the importance of brand identity, which is why we offer personalized customization services. Your logo can be elegantly integrated into the device's startup screen and etched onto the machine's body. If you need to customize the logo for your machine, please contact us via email at info@cantaesthetic.com.
Thanks for subscribing!
This email has been registered!
Shop the look
Choose Options
Popular Products
Popular Products